www.seguridadelectrica.com
 Tuesday 07th of February 2012 03:23:25 PM 
Español English

Volt Meter Plug and Shocket-Outlet - IEC 60335-1

Equipment designed and developed for the test in paragraph 22.5 of IEC 60335-1 standard.

22.5 Appliances intended to be connected to the supply mains by means of a plug shall be constructed so that in normal use there is no risk of electric shock from charged capacitors having a rated capacitance exceeding 0,1 μF, when the pins of the plug are touched.

Compliance is checked by the following test.

The appliance is supplied at rated voltage. Any switch is then placed in the off position and the appliance is disconnected from the supply mains at the instant of voltage peak. One second after disconnection, the voltage between the pins of the plug is measured with an instrument that does not appreciably affect the value to be measured.

The voltage shall not exceed 34 V.

Make a test:

  • First, check the setpoints on the equipment.
  • Connect the equipment to be tested in the socket test.
  • Position yourself on the screen No. 3 (home screen test).
  • Press the Start button, and automatically the equipment start the test.
  • Actuate the contactor that feeds power to the equipment under test.
  • The equipment, start to discount the Time ON.
  • After elapsed time of testing, the equipment under test will shut down, and the equipment start to deduct the waiting time.
  • When it reaches 0, the equipment, measure the residual voltage left in the equipment under test, the display screen and a beep sounds indicating that the test is complete.

 

Volt Meter Plug and Shocket-Outlet - Images
front Socket test.



 

Equipment Specifications:

 
  • Power Supply: 220Vca, 50 Hz, single-phase (115 Vac optional).
  • Test Voltage : According to input voltage.
  • MAX Current test: 5 Aca.
  • Display LCD.
  • Totally controlled by microprocessor.
  • To test equipments: Class I.
  • Verification SET (optional).
  • Dimensions: 260mm x 200mm x 140mm(h)
  • Weight: 2,1 Kg
  • According to: IEC 60335-1 (Paragraph 22.5).
  • Calibration report.

 

Filamento Incandescente (Glow Wire Apparatus)
Glow Wire Test Apparatus 2009

Encaminamiento Eléctrico (Tracking Index Apparatus)
Tracking Index Test Apparatus

Spark Test
Spark Test / Spark Tester

Laboratory Equipments:

DEVICES:

SOFTWARE + PC + ADQ.:

POWER EFFICIENCY:

HOME   :::   PRODUCTS LIST   :::   SOFTWARES LIST   :::   ABOUT SE.COM   :::   CONTACT US
 
Equipments installed in: ARABIA SAUDITA | ARGENTINA | AUSTRALIA | BAHRAIN | BRASIL | CHILE | COLOMBIA | EGIPTO | ESPAÑA | GRECIA | INDIA | ITALIA | JAPÓN | MÉXICO | NORUEGA | REINO UNIDO | SINGAPUR | SUIZA | URUGUAY | USA | See Map

Copyright © 2004, Seguridad Eléctrica. com (Se.com) . Todos los derechos reservados
- *** - ***
Rosario - Santa Fe - República Argentina